Add to Favorites
Share

Temperature Control Euipment For Reactor

  • Description
Product Detail

    Heat Application- conducting Oil Heater in Temperature Control for Chemical Reactor

    The reaction kettle temperature control effect is to determine the product quality, production efficiency. Under normal circumstances the application of temperature control use different temperature heat transfer oil directly into the reactor jacket, in order to adjust the temperature transfer to the reactor, this often makes the reactor jacket fluid quite chaotic, kettle Temperature is difficult to achieve the expected results. In response to reslove this problem, we design a reactor oil circulating heater, the principle is to use the heat transfer oil through the pump, the heat  through heat exchanger into the reactor, when it need to cool down, start the cooling system, at same time the heater stops working. Just to reach the temperature inside the reactor at the setting time, then it continue to keep the temperature, so only the usage of heat conducting oil heater can make the kettle temperature faster and more accurately to reach the best temperature.

    Reactor temperature control machine, reactor heating oil circulation heating equipment selection parameters:

    1, the size of the reactor;

    2, the weight of reactor;

    3, the reactor jacket or coil volume;

    4, the reactor of the material parameters: density, specific heat, viscosity and so on

    5, the reactor material required to achieve the temperature, and heating to the temperature of the time requirements;

    6, reactor jacket is how much the import and export;

    7, the need for refrigeration or explosion-proof;

    8, whether the reactor can provide the drawings;



    Model

    Unit

    HLET-10

    HLET-20

    HLET-30

    HLET-40

    HLET-50

    HLET-75

    HLET-100

    HLET-150

    Temp Range

    ?

    Normal temperature-300?

    Temp.Control Accuracy


    PID±1?

    Power Supply


    AC3?380V   50HZ3P+E(5M)

    Heat Transfer Medium


    Qil

    Cooling Method


    Indirect Cooling

    Expansion Tank Capacity

    L

    24

    24

    28

    55

    55

    (100)

    (150)

    (250)

    Heating Capacity

    KW

    18

    18/24

    24/36

    36/50

    40/60

    50/75

    80/100

    100/150

    Pump Power

    KW

    0.75

    1.5

    2.2

    3.0

    4.0

    5.5

    7.5

    11.0

    Pump Folw

    L/MIN

    1.5

    1.5

    10

    12.5

    16

    12.5(18)

    25(30)

    12.8(18)

    Pump Pressure

    KG/CM2

    2.2

    2.2

    2.8

    3.0

    3.2

    5.0(4.0)

    5.0(4.8)

    8.7(7.0)

    Power Supply

    KW

    13

    20

    28

    40

    50

    62

    132

    162

    Alert Function


    Shortage/Overheating/Overload

    Cooling Water Pipe

    INCH

    1/2

    1/2

    1/2

    1/2

    1/2

    1/2

    3/4

    3/4

    Circulation water Pipe

    INCH

    3/4

    3/4

    1

    1-1/4

    1-1/4

    1-1/2

    2

    2.5

    Size(L*W*H)

    MM

    L=1150
      W=500
      H=1000

    L=1150
      W=500
      H=1000

    L=1450
      W=580
      H=1250

    L=1600
      ,
      W=630
      H=1200

    L=1600
      W=550
      H=1200

    L=1600
      W=550
      H=1200

    L=1600
      W=600
      H=1400

    L=1600
      W=600
      H=1400

Send your message to this supplier
To:  

Holy City Limited

* Content:  

For better quotations, include:

- A self introduction